Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
1.
Biologicals ; 46: 57-63, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28082100

RESUMO

Nucleic acid amplification techniques (NAT) are routinely used for clinical diagnostics and monitoring hepatitis B virus (HBV) infections, and are implemented on a voluntary basis for blood screening. A collaborative study was performed to evaluate a replacement WHO International Standard for HBV for the standardization of NAT. Two lyophilised HBV candidates were evaluated by 16 laboratories worldwide, alongside the existing HBV International Standard. The overall mean potency estimates for the candidate samples 1 and 2, relative to sample 3 (2nd HBV International Standard), from quantitative assays, were 5.93 and 5.98 log10 International Units (IU)/mL respectively. The variability in individual laboratory mean estimates for samples 1-3 for quantitative assays was ∼0.3 log10 IU/mL. The inter-laboratory variability for qualitative assays was higher. Accelerated thermal degradation studies indicate that both lyophilised candidates are stable and suitable for long-term use. Overall, the results suggested that both candidates were suitable as replacement International Standards. Sample 1 (NIBSC code 10/264) was established as the 3rd WHO International Standard for HBV for NAT with an assigned potency of 850,000 IU/mL (∼5.93 log10 IU/mL), when reconstituted in 0.5 mL of nuclease-free water. It is intended for the calibration (in IU) of secondary reference materials used in HBV NAT.


Assuntos
DNA Viral/genética , Vírus da Hepatite B/genética , Técnicas de Amplificação de Ácido Nucleico/métodos , Técnicas de Amplificação de Ácido Nucleico/normas , Liofilização , Humanos , Cooperação Internacional , Padrões de Referência , Reprodutibilidade dos Testes , Organização Mundial da Saúde
2.
Biologicals ; 44(5): 423-33, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27461128

RESUMO

Variability in viral load measurements using nucleic acid amplification techniques (NAT) has a significant impact on the management of Epstein-Barr virus (EBV)-associated diseases, and has highlighted a need for standardisation of these measurements. The aim of this collaborative study was to evaluate the suitability of a range of candidate reference materials to harmonise EBV viral load measurements in a wide range of NAT assays. Candidate materials included lyophilised and liquid whole virus preparations of the EBV B95-8 strain, and preparations of Namalwa and Raji cells. Variability between the individual laboratory mean estimates for each candidate was 2.5 log10 copies/mL. The agreement between laboratories was improved when the potency of each candidate was expressed relative to the lyophilised B95-8 preparation. The results of the study indicate the suitability of this candidate as the 1st WHO International Standard for EBV for NAT. It was established in October 2011 by the WHO's Expert Committee on Biological Standardisation with an assigned potency of 5 × 10(6) International Units (IU) (NIBSC code 09/260). It is intended to be used for the calibration of secondary reference materials, used in EBV NAT assays, in IU, thereby improving the comparability of patient viral load measurements.


Assuntos
DNA Viral/química , DNA Viral/normas , Herpesvirus Humano 4/química , Técnicas de Amplificação de Ácido Nucleico/normas , Animais , Linhagem Celular , Humanos , Camundongos , Técnicas de Amplificação de Ácido Nucleico/métodos
3.
Clin Infect Dis ; 63(5): 583-9, 2016 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-27307504

RESUMO

BACKGROUND: Interassay harmonization of cytomegalovirus (CMV) DNA measurement is important for infection management. Uncertainty exists regarding the result harmonization achievable in patient plasma samples using quantitative polymerase chain reaction (qPCR) assays with calibrators now traceable to the First World Health Organization International Standard (IS) for CMV DNA. METHOD: Serial dilutions of the IS and a blinded panel of 40 genotyped CMV DNA-positive pooled plasma samples and 10 negative plasma samples were tested by 6 laboratories using 10 qPCR assays calibrated to the IS. Each clinical sample was constructed using plasma from a single unique transplant recipient. RESULTS: The variance for individual CMV DNA-positive samples was greater for clinical samples (median, 1.50 [range, 1.22-2.82] log10 IU/mL) than for IS dilutions (median, 0.94 [range, 0.69-1.35] log10 IU/mL) (P < .001); 58.9% of all clinical sample results and 93.6% of IS dilution results fell within ±0.5 log10 IU/mL of the mean viral load of each sample. Result variability was not impacted by either genotype or quantitative levels of CMV DNA. Testing procedure differences can significantly influence results, even when analyte-specific reagents are identical. For clinical samples, all assays demonstrated result bias (P < .008). Assays with amplicon sizes ≤86 bp had significantly higher results compared to assays with larger amplicon sizes (≥105 bp) (P < .001). CONCLUSIONS: The variability in CMV DNA results reported on individual samples has been reduced by the IS, but ongoing clinically relevant variability persists, preventing meaningful interassay result comparison.


Assuntos
Infecções por Citomegalovirus/virologia , Citomegalovirus/genética , DNA Viral/sangue , Citomegalovirus/isolamento & purificação , Infecções por Citomegalovirus/sangue , Infecções por Citomegalovirus/diagnóstico , Técnicas de Genotipagem , Humanos , Internacionalidade , Tipagem Molecular , Padrões de Referência , Sensibilidade e Especificidade , Carga Viral/normas
4.
J Clin Virol ; 82: 173-180, 2016 09.
Artigo em Inglês | MEDLINE | ID: mdl-27345251

RESUMO

BACKGROUND: The WHO International Standard (IS) for hepatitis B surface antigen (HBsAg) is used to standardize HBsAg assays. Stocks of the 2nd IS for HBsAg are depleted. The proposal to establish its replacement was endorsed by WHO in 2012. OBJECTIVE: Preparation of a freeze-dried candidate 3rd IS (NIBSC 12/226); evaluation of its suitability in a WHO international collaborative study; calibration of its potency in International Units (IU). STUDY DESIGN: The 3rd IS is based on plasma-derived, purified, inactivated HBsAg from Vietnam. Qualitative and quantitative HBsAg assays were used to evaluate 12/226 alongside the 2nd IS and 1st IS. Blinded study samples included a duplicate of 12/226, a negative control and two diluted plasma samples representing hepatitis B virus (HBV) genotypes A and B. RESULTS: Twelve laboratories from 9 countries returned 22 data sets from 15 methods. The overall geometric mean potency of 12/226 is 47.3IU/mL (±13% CV) when compared to the 2nd IS with HBV subgenotype A2. The 3rd IS has HBV subgenotype B4 with a heterogeneous HBsAg subtype population of ayw1 and adw2. Some genotype-dependent effects on the inter-laboratory variability were observed but overall mean potencies were virtually identical irrespective of the IS used for calibration. Stability studies indicate that the candidate is stable for long-term use. CONCLUSIONS: 12/226 was established in October 2014 by the WHO Expert Committee on Biological Standardization as the 3rd IS for HBsAg with a potency of 47.3IU per ampoule maintaining the continuity in the standardization of HBsAg assays.


Assuntos
Antígenos de Superfície da Hepatite B/análise , Hepatite B/diagnóstico , Imunoensaio/normas , Padrões de Referência , Testes Sorológicos/normas , Humanos , Cooperação Internacional , Organização Mundial da Saúde
5.
Biologicals ; 44(4): 242-251, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27179913

RESUMO

Variability in the performance of nucleic acid amplification technology (NAT)-based assays presents a significant problem in the diagnosis and management of human cytomegalovirus (HCMV) infections. Here we describe a collaborative study to evaluate the suitability of candidate reference materials to harmonize HCMV viral load measurements in a wide range of NAT assays. Candidate materials comprised lyophilized Merlin virus, liquid Merlin virus, liquid AD169 virus, and purified HCMV Merlin DNA cloned into a bacterial artificial chromosome. Variability in the laboratory mean HCMV concentrations determined for virus samples across the different assays was 2 log10. Variability for the purified DNA sample was higher (>3 log10). The agreement between laboratories was markedly improved when the potencies of the liquid virus samples were expressed relative to the lyophilized virus candidate. In contrast, the agreement between laboratories for the purified DNA sample was not improved. Results indicated the suitability of the lyophilized Merlin virus preparation as the 1st WHO International Standard for HCMV for NAT. It was established in October 2010, with an assigned potency of 5 × 10(6) International Units (IU) (NIBSC code 09/162). It is intended to be used to calibrate secondary references, used in HCMV NAT assays, in IU.


Assuntos
Citomegalovirus/genética , DNA Viral/genética , Técnicas de Amplificação de Ácido Nucleico/métodos , Técnicas de Amplificação de Ácido Nucleico/normas , Calibragem , Citomegalovirus/fisiologia , Infecções por Citomegalovirus/diagnóstico , Infecções por Citomegalovirus/virologia , Liofilização , Humanos , Cooperação Internacional , Laboratórios/normas , Padrões de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Carga Viral/genética , Organização Mundial da Saúde
6.
J Immunol Methods ; 397(1-2): 1-7, 2013 Nov 29.
Artigo em Inglês | MEDLINE | ID: mdl-23948423

RESUMO

Two candidate preparations of human sequence recombinant Interleukin-2 (IL-2) were formulated and lyophilized at NIBSC prior to evaluation in a collaborative study for their suitability to serve as a replacement international standard. The preparations were tested by eight laboratories using in vitro bioassays and immunoassays. The candidate preparation 86/500 was judged suitable to serve as a replacement international standard based on the data obtained for activity and stability. On the basis of the results reported here, the preparation coded 86/500 was established by the WHO Expert Committee on Biological Standardisation (ECBS) in 2012 as the WHO 2nd IS for human IL-2 with an assigned value for IL-2 activity of 210IU/ampoule. Calibration of the 2nd IS is primarily based on the bioassay in use in various laboratories and relies exclusively on the estimates calculated relative to the WHO 1st IS for continuity of the IU.


Assuntos
Interleucina-2/normas , Proteínas Recombinantes/normas , Bioensaio/normas , Calibragem , Humanos , Imunoensaio/normas
9.
J Immunol Methods ; 380(1-2): 1-9, 2012 Jun 29.
Artigo em Inglês | MEDLINE | ID: mdl-22464938

RESUMO

One candidate preparation of human sequence recombinant transforming growth factor-ß3 (TGF-ß3) was formulated and lyophilized at NIBSC prior to evaluation in a collaborative study for its suitability to serve as an international standard. The preparation was tested by 8 laboratories using in vitro bioassays and immunoassays. The candidate preparation 09/234 was judged suitable to serve as an international standard based on the data obtained for biological activity and stability. On the basis of the results reported here, the preparation coded 09/234 was established by the WHO Expert Committee on Biological Standardisation (ECBS) as the WHO 1st IS for human TGF-ß3 with an assigned value for TGF-ß3 activity of 19,000 IU/ampoule.


Assuntos
Fator de Crescimento Transformador beta3/normas , Bioensaio/métodos , Bioensaio/normas , Humanos , Imunoensaio/métodos , Imunoensaio/normas , Padrões de Referência
11.
J Immunol Methods ; 367(1-2): 63-9, 2011 Mar 31.
Artigo em Inglês | MEDLINE | ID: mdl-21334342

RESUMO

Five candidate preparations of human sequence recombinant granulocyte-colony stimulating factor (G-CSF) were formulated and lyophilized at NIBSC prior to evaluation in a collaborative study for their suitability to serve as a replacement International Standard (IS). The preparations were tested by 13 laboratories using in vitro bioassays. The candidate preparation 09/136 was judged suitable to serve as a replacement international standard based on the data obtained for biological activity and stability. On the basis of the results reported here, the preparation coded 09/136 was established by the WHO Expert Committee on Biological Standardization (ECBS) as the 2nd IS for human G-CSF with an assigned value for G-CSF activity of 95,000 IU/ampoule. Calibration of the 2nd IS is primarily based on the bioassay in use in various laboratories and relies entirely on the estimates calculated relative to the WHO 1st IS for continuity of the IU.


Assuntos
Fator Estimulador de Colônias de Granulócitos/normas , Animais , Linhagem Celular , Estabilidade de Medicamentos , Fator Estimulador de Colônias de Granulócitos/farmacologia , Humanos , Camundongos , Padrões de Referência , Organização Mundial da Saúde
12.
Int J Cancer ; 126(12): 2969-83, 2010 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-19904756

RESUMO

A World Health Organization collaborative study was conducted to evaluate candidate international standards for human papillomavirus (HPV) Type 16 DNA (NIBSC code 06/202) and HPV Type 18 DNA (NIBSC code 06/206) for use in the amplification and detection steps of nucleic acid-based assays. The freeze-dried candidate international standards were prepared from bulk preparations of cloned plasmid containing full-length HPV-16 or HPV-18 genomic DNA. Nineteen laboratories from 13 countries participated in the study using a variety of commercial and in-house quantitative and qualitative assays. The data presented here indicate that, upon freeze-drying, there is no significant loss in potency for the candidate HPV-18 DNA and a slight loss in potency for the candidate HPV-16 DNA; although this is likely not scientifically relevant when assay precision is considered. In general, the individual laboratory mean estimates for each study sample were grouped +/- approximately 2 log(10) around the theoretical HPV DNA concentration of the reconstituted ampoule (1 x 10(7) HPV genome equivalents/mL). The agreement between laboratories is improved when potencies are made relative to the candidate international standards, demonstrating their utility in harmonizing amplification and detection steps of HPV-16 and -18 DNA assays. Degradation studies indicate that the candidate international standards are extremely stable and suitable for long-term use. Based on these findings, the candidate standards were established as the 1st WHO international standards for HPV-16 DNA and HPV-18 DNA, each with a potency of 5 x 10(6) international units (IU) per ampoule or 1 x 10(7) IU mL(-1) when reconstituted as directed.


Assuntos
Técnicas de Laboratório Clínico/normas , DNA Viral/análise , Papillomavirus Humano 16/genética , Papillomavirus Humano 18/genética , Técnicas de Amplificação de Ácido Nucleico/normas , Padrões de Referência , Organização Mundial da Saúde , Humanos , Cooperação Internacional , Reação em Cadeia da Polimerase
18.
Malar J ; 7: 139, 2008 Jul 24.
Artigo em Inglês | MEDLINE | ID: mdl-18652656

RESUMO

BACKGROUND: In order to harmonize results for the detection and quantification of Plasmodium falciparum DNA by nucleic acid amplification technique (NAT)-based assays, a World Health Organization (WHO) collaborative study was performed, evaluating a series of candidate standard preparations. METHODS: Fourteen laboratories from 10 different countries participated in the collaborative study. Four candidate preparations based upon blood samples parasitaemic for P. falciparum were evaluated in the study. Sample AA was lyophilized, whilst samples BB, CC and DD were liquid/frozen preparations. The candidate standards were tested by each laboratory at a range of dilutions in four independent assays, using both qualitative and quantitative NAT-based assays. The results were collated and analysed statistically. RESULTS: Twenty sets of data were returned from the participating laboratories and used to determine the mean P. falciparum DNA content for each sample. The mean log10 "equivalents"/ml were 8.51 for sample AA, 8.45 for sample BB, 8.35 for sample CC, and 5.51 for sample DD. The freeze-dried preparation AA, was examined by accelerated thermal degradation studies and found to be highly stable. CONCLUSION: On the basis of the collaborative study, the freeze-dried material, AA (NIBSC code No. 04/176) was established as the 1st WHO International Standard for P. falciparum DNA NAT-based assays and has been assigned a potency of 10(9) International Units (IU) per ml. Each vial contains 5 x 10(8) IU, equivalent to 0.5 ml of material after reconstitution.


Assuntos
DNA de Protozoário/genética , Técnicas de Amplificação de Ácido Nucleico/normas , Plasmodium falciparum/genética , Organização Mundial da Saúde , Animais , Bioensaio/métodos , Bioensaio/normas , Técnicas de Laboratório Clínico/normas , Cooperação Internacional , Técnicas de Amplificação de Ácido Nucleico/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...